Special Application
Trigger Port
To define the TCP/UDP port range to monitor, when initiating from the home
network, the public ports configured in this entry will be activated.
Trigger Type
Defines the protocol type: TCP, UDP or both of the trigger ports.
Public Port
This column defines the public ports opened when the trigger ports were seen.
You can enter multiple ports, delimited by comma, or a range of port by dash.
White space will be neglect.
Public Type
Defines the protocol type, TCP/UDP/Both, of the public ports.
Comment
Let you put some notes to describe this entry.
Enabled
Enable this entry.